PluginWorld
Co

coolercontrol-mcp

MCP

Enables MCP clients such as Claude to read temperatures, fan speeds, power and clocks from a CoolerControl daemon, and to change fan profiles, fixed duty speeds, modes, functions, alerts and custom sensors through its REST API. Write operations are gated behind a token with write access, with an optional minimum-duty floor guarding against accidentally stopping a pump or fan.

@ryanpag3 · v0.2.0 · MIT License · updated today

SECURITY

B

SCORE

69

STARS

▲ 1

PLUG IN

git clone https://github.com/ryanpag3/coolercontrol-mcp.git

See the README to configure this MCP server

README

coolercontrol-mcp

An MCP server for CoolerControl. It lets Claude and other MCP clients read your temperatures and fan speeds, and change fan profiles, fixed speeds and modes, through the CoolerControl daemon's REST API.

Tested against CoolerControl 5.1.1.

Tools

All 32 tools. ✏️ marks tools that change something; they need a token with Write Access.

Area Tool What it does
Monitoring get_status Latest temperatures (°C), fan rpm and duty, power and clocks; optionally one device or channel
list_devices Devices, their fan channels and their temperature sensors
get_channel_settings What each fan channel is set to: a profile, a fixed duty, or the default
get_health Daemon version, uptime and warning count
Fan channels set_fixed_speed ✏️ Set a channel to a fixed duty % (refuses values below COOLERCONTROL_MIN_DUTY)
apply_profile ✏️ Assign a profile to a channel
reset_channel ✏️ Return a channel to its hardware default
Profiles list_profiles Profiles with their curves and temperature sources
create_profile ✏️ Create a Fixed, Graph, Mix or Overlay profile
update_profile ✏️ Change some fields of a profile; the rest stay as they are
delete_profile ✏️ Delete a profile; refuses while anything uses it unless force is set
Modes list_modes Saved modes and which one is active
get_mode The channel settings saved in a mode
create_mode ✏️ Save the current settings of every channel as a new mode
update_mode ✏️ Rename a mode and/or re-save it from the current settings
duplicate_mode ✏️ Copy a mode
delete_mode ✏️ Delete a mode
activate_mode ✏️ Apply a mode's saved settings
Functions list_functions Functions that control how quickly profiles change duty
create_function ✏️ Create a function; unset fields copy the Default Function
update_function ✏️ Change some fields of a function
delete_function ✏️ Delete a function; refuses while a profile uses it unless force is set
Alerts list_alerts Alerts and the recent alert log
create_alert ✏️ Create an alert on a temperature, duty, load, rpm or frequency
update_alert ✏️ Change some fields of an alert
delete_alert ✏️ Delete an alert
Custom sensors list_custom_sensors Custom sensors
create_custom_sensor ✏️ Create a sensor that mixes, offsets or averages other sensors, or reads a file
update_custom_sensor ✏️ Change some fields of a custom sensor
delete_custom_sensor ✏️ Delete a custom sensor; refuses while a profile uses it unless force is set
Any other endpoint list_api_endpoints List the 83 REST endpoints a token can call
call_api ✏️ Call any of them: lighting, LCD images, calibration, name overrides, daemon settings, stats, detection, power profiles, logs, metrics

Devices can be given by uid, uid prefix (8+ characters) or exact name. Channels can be given by name (fan1) or label (Intake). Profiles, modes, functions and alerts can be given by uid or name.

Not supported: login and passwords, access-token management, daemon shutdown, plugins, stress tests, saving UI settings and the live event streams. CoolerControl accepts only a browser session for these, not a token.

Setup

  1. Create a token. In the CoolerControl UI, open Access Protection → Create Token. Leave Write Access off for a monitoring-only token; the daemon then rejects the write tools with a clear error. Turn it on to let the client change fan settings.

  2. Build:

    git clone https://github.com/ryanpag3/coolercontrol-mcp.git
    cd coolercontrol-mcp
    npm install   # also builds dist/
    
  3. Register it with your MCP client.

    Claude Code:

    claude mcp add coolercontrol -s user \
      -e COOLERCONTROL_TOKEN=cc_... \
      -- node /path/to/coolercontrol-mcp/dist/index.js
    

    Claude Desktop (or any client that uses a JSON config):

    {
      "mcpServers": {
        "coolercontrol": {
          "command": "node",
          "args": ["/path/to/coolercontrol-mcp/dist/index.js"],
          "env": { "COOLERCONTROL_TOKEN": "cc_..." }
        }
      }
    }
    

Docker

A multi-arch image (amd64, arm64) is published to GHCR. The daemon listens on 127.0.0.1 by default, so the container needs --network host to reach it:

claude mcp add coolercontrol -s user -e COOLERCONTROL_TOKEN=cc_... -- \
  docker run -i --rm --network host -e COOLERCONTROL_TOKEN ghcr.io/ryanpag3/coolercontrol-mcp:latest
{
  "mcpServers": {
    "coolercontrol": {
      "command": "docker",
      "args": ["run", "-i", "--rm", "--network", "host", "-e", "COOLERCONTROL_TOKEN",
               "ghcr.io/ryanpag3/coolercontrol-mcp:latest"],
      "env": { "COOLERCONTROL_TOKEN": "cc_..." }
    }
  }
}

Tags: latest (master), sha-<commit>, and X.Y.Z / X.Y for vX.Y.Z git tags.

Configuration

Variable Default
COOLERCONTROL_TOKEN (required) cc_... access token
COOLERCONTROL_URL http://localhost:11987 Daemon URL. Use https:// for a remote daemon with TLS enabled
COOLERCONTROL_MIN_DUTY 20 Lowest duty % that set_fixed_speed will apply. A guard against stopping a pump or fan by accident; set it to 0 to allow anything the hardware accepts
COOLERCONTROL_INSECURE_TLS false Accept self-signed certificates

The minimum-duty floor applies only to set_fixed_speed. Profiles keep whatever curve you gave them in CoolerControl.

Development

npm run build   # tsc → dist/
npm test        # vitest
npx @modelcontextprotocol/inspector -e COOLERCONTROL_TOKEN=cc_... node dist/index.js

License

MIT